(ADI) Low Power Analog Front-End Chip ADAS1000 BCPZ | 24 bit, 2 MS/s, LFCSP-56
The ADAS1000BCPZ is an analog front end (AFE) for bioelectrical signal acquisition, especially for electrocardiogram (ECG) measurements.IntroductionThe ADAS1000BCPZ is a low-power 5-electrode electrocardiogram (ECG) analog front-end chip for the acqui…
The ADAS1000BCPZ is an analog front end (AFE) for bioelectrical signal acquisition, especially for electrocardiogram (ECG) measurements.
Introduction
The ADAS1000BCPZ is a low-power 5-electrode electrocardiogram (ECG) analog front-end chip for the acquisition and processing of bioelectrical signals. The ADAS1000BCPZ consumes 11 MW at 1 lead, 15 MW at 3 leads, and 21mW at all electrodes . The ADAS1000BCPZ supports 5 ECG channels and 1 drive lead, and multiple ics in parallel can be used for measurements with 10 or more electrodes . In addition, the ADAS1000BCPZ has built-in AC and DC lead drop detection, 3 lead built-in pace-signal detection algorithms, chest impedance measurement (internal/external path), optional reference leads, adjustable noise and power control, and turn-off mode .
Because ECG systems are widely used, the ADAS1000BCPZ uses a power/noise adjustment structure to reduce noise at the expense of increased power consumption. Some unused signal acquisition channels can be closed, or the data rate can be reduced to achieve the purpose of saving power.
The ADAS1000BCPZ supports SPI/QSPI™/DSP compatible serial interface to provide lead or electrode data, Comply with AAMI EC11:1991/(R)2001/(R)2007, AAMI EC38 R2007, IEC60601-1 ed.3.0b :2005 and other standards .
Application field
The ADAS1000BCPZ is suitable for a wide range of medical devices, including:
Bedside patient monitoring
Portable telemetry
Dynamic ECG monitor
Automatic External defibrillator (AED)
Cardiac defibrillation
Portable monitor
A pacemaker programmer
Patient transport
Pressure test
The ADAS1000BCPZ has the following key features:
Bioelectrical signal input; Digital signal output
Five acquisition (ECG) channels and one drive lead
Multiple ics in parallel can be used for measurements with 10 or more electrodes
The master device ADAS1000 or ADAS1000-1 is used with the slave device ADAS1000-2
Ac and DC lead drop detection
3 leads built-in pacing signal detection algorithm
Support for user initiation signals
Thoracic impedance measurement (internal/external path)
Reference lead is optional
Adjustable noise and power control, off mode
Low power consumption
11 mW (1 lead), 15 mW (3 leads), 21 mW (all electrodes)
Provide lead or electrode data
Support AAMI EC11:1991/(R)2001/(R)2007, AAMI EC38
R2007, EC13:2002/(R)2007, IEC60601-1 ed. 3.0b :2005,
IEC60601-2-25 ed. 2.0 :2011, IEC60601-2-27 ed. 2.0
b:2005, IEC60601-2-51 ed. 1.0b :2005
Fast overload recovery
Low or high data output rate
Serial interface: SPI/QSPI™/DSP compatible
The ADAS1000BCPZ comes in a 56-pin LFCSP package (9 mm x 9 mm)
For sample or quotation of [ADAS1000BCPZ], please contact www.hkmjd.com for details!
Time:2025-03-29
Time:2025-03-29
Time:2025-03-29
Time:2025-03-29
Contact Number:86-755-83294757
Enterprise QQ:1668527835/ 2850151598/ 2850151584/ 2850151585
Business Hours:9:00-18:00
E-mail:sales@hkmjd.com
Company Address:Room1239, Guoli building, Zhenzhong Road, Futian District, Shenzhen, Guangdong
CopyRight ©2022 Copyright belongs to Mingjiada Yue ICP Bei No. 05062024-12
Official QR Code
Links: