ADPD7000BCBZ multi-mode sensor analog front end, let wearable devices "know you better"
Description:The ADPD7000BCBZ is a highly integrated analog front end (AFE) designed to measure a wide range of vital signs signals.The ADPD7000 has a transceiver optical channel with up to eight leds that excite and measure the return signal on four c…
Description:
The ADPD7000BCBZ is a highly integrated analog front end (AFE) designed to measure a wide range of vital signs signals.
The ADPD7000 has a transceiver optical channel with up to eight leds that excite and measure the return signal on four current inputs. Signal chain suppression of misalignment and interference without optical filters or external DC elimination circuits. ECG signal acquisition ensures low noise diagnostic level measurements in a variety of interference sources, with a drive reference for common-mode rejection and lead break detection for the drop electrode.
Feature
Multi-mode analog front end
Optical channel
4 input channels, with a variety of operating modes, suitable for various sensor measurements
4-channel processing with synchronous sampling
12 programmable time slots for synchronous sensor measurements
Flexible input multiplexing for single-end sensor measurement
8 LED drivers, can drive 2 of them at the same time
Flexible sampling rate: 0.004Hz to 9kHz (using internal oscillator)
Ac environment light suppression: 78dB to 100Hz
Total LED peak driving current: 400mA
Independent environment eliminates DAC when TIA input, 9-bit control up to 300μA
Independent LED DC eliminates DAC when TIA input, 7-bit control up to 190μA
ECG channel
RTI noise at diagnostic bandwidth: <1µV RMS
High input impedance: 20GΩ
Accepts DC differential input range up to ±1.2V
CMRR: 115dB
Flexible 4-electrode configuration to support a variety of applications
Ac lead break detection and DC lead break detection
Supports normally open, low power consumption, and lead on-detection
BIA channel
Low power consumption, high precision excitation path
Configurable excitation frequency up to 250kHz
Sine-wave excitation with 12-bit DAC
High precision, large unbalance contact impedance ≤20kΩ
Configurable receiving filter with low noise design
Complex impedance measuring engine
Integrated current limiting resistor
EDA channel
Support voltage and current excitation
The measurement range is 10kΩVAC to 100MΩ with a resolution of 1nS
DFT and extraction to achieve high precision measurement results
Support SPI communication
704 bytes FIFO
Applications
Wearable health and fitness monitors: heart rate, heart rate variability, pulse oxygen saturation, body impedance analysis, hydration analysis and sleeveless non-invasive blood pressure measurement
Clinical patient monitor: small bedside patient monitor, home portable patient monitor, small remote patient monitor
Industrial monitoring: Particle, aerosol and gas detection
Electrical conductivity detection
Time:2024-11-20
Time:2024-11-20
Time:2024-11-20
Time:2024-11-20
Contact Number:86-755-83294757
Enterprise QQ:1668527835/ 2850151598/ 2850151584/ 2850151585
Business Hours:9:00-18:00
E-mail:sales@hkmjd.com
Company Address:Room1239, Guoli building, Zhenzhong Road, Futian District, Shenzhen, Guangdong
CopyRight ©2022 Copyright belongs to Mingjiada Yue ICP Bei No. 05062024-12
Official QR Code
Links: